Polarwool

COMPARISON table for common insulation materials.

  sheep's wool
cork woody fiber
insulating panels
expanded polystyrene glass wool
rock wool
Thermal conductivity λ 0,037-0,042 0,040-0,045 0,51-0,056 0,035-0,044 0,034-0,042
Steam resistance number 1 1,5-30 4-9 20-100 1-1,3
Energy consumption in manufacturing process low low medium high low
Pollution emission during manufact process low low / very high medium
Precautions required during installation none none face mask none face mask, gloves
Availability of raw materials natural natural natural limited abundant
Recyclable YES sometimes YES NO NO
Transport costs medium high low high low

Thermal insulation specifications.

"λ" thermal conductivity and "cs" specific thermal conductance were determined using the hot place and guard ring method according to ISO 8302/91 by Istituto Giordano.

  weights
gr/m2
density
kg/m3
thickness
mm
thermal conductivity λ
w/m.K
thermal resistance
R=s/λ
thermal conductance
cs=w/m2.K
resistenza al passaggio del vapore acqueo
coefficiente µ
Polarwool 1250 1250 25 50 0,040 1,250 0,800 1 - 1,5
Polarwool 1000 1000 20 50 0,0428 1,168 0,854 1 - 1,5
Polarwool 800 800 16 50 0,0437 1,144 0,872 1 - 1,5
Polarwool 500 500 10 50 0,0538 0,929 1,07 1 - 1,5

Technical specifications and acoustic absorption coefficient graph for Polarwool® 500. The acoustic absorption coefficient "s" was determined according to ISO 354, 1988 edition, by Istituto Giordano.